Verified Field Diagnostics

Linger troubleshooting: errors we actually hit

Every entry below was reproduced in our own install test on 2026-11-26, Linger 0.1.10. We document the exact symptoms, root causes found in local log files, and practical fixes or current statuses.

1. BYOK test says "Connected" but the agent run fails

Symptom:

The BYOK settings screen shows a green "Connected · 128k context" badge after clicking Test. However, when sending a real message in the Linger chat window, the agent immediately crashes with the message: "Couldn't finish. Its AI app stopped with an error."

What it means:

Checking Linger's internal daemon log (~/.simplexai/instances/desktop/native/logs/node-services.log) shows: RuntimeExecutionError: Claude Code runtime (2.1.288) api_error, statusCode 400. While Linger's lightweight connection tester sends a simple query that Google's OpenAI-compatible endpoint accepts, the actual agent runner compiles a complex multi-turn JSON payload containing tool definitions and agent system prompts. Google's /v1beta/openai translation layer rejected this payload with an HTTP 400 bad request error.

Status & Fix:

Status: Reproduced by us on 2026-11-26 (v0.1.10); no confirmed fix yet within Gemini BYOK. A passing connection test does not guarantee agent runs.

Workaround: The subscription-based runtimes (Claude Code or Codex direct sign-in) are the primary supported path in Linger. If using BYOK, use an endpoint whose OpenAI compatibility layer accepts complex tool calling schemas.

2. gemini-2.5-flash returns 404 "no longer available to new users"

Symptom:

Clicking Test in the BYOK configuration with Model ID set to gemini-2.5-flash produces: "HTTP 404: the address or the model was not found."

What it means:

Querying Google AI Studio's API directly reveals the root cause: "This model models/gemini-2.5-flash is no longer available to new users." Newly generated Google AI Studio API keys cannot access legacy 2.5 series flash models.

Fix:

Fix: In the BYOK Model ID field, enter gemini-3-flash-preview instead. Connection testing immediately returns "Connected · 128k context".

3. Anthropic Messages path returns 404

Symptom:

Attempting to configure Gemini BYOK with Path set to empty and Endpoint set to /messages returns HTTP 404.

What it means:

Pairing Google's Base URL (https://generativelanguage.googleapis.com or .../v1beta) with an Anthropic-formatted /messages endpoint is incompatible with Google's API route structure.

Fix:

Fix: Use the OpenAI-compatible preset:

  • Base URL: https://generativelanguage.googleapis.com
  • Path: /v1beta/openai
  • Endpoint: /chat/completions

4. "No local model fits this computer" / "GPU not supported"

Symptom:

The Quick Install wizard displays "No local model fits this computer", and under Settings → Models → Local model, all downloadable models display "Can't download · GPU not supported".

What it means:

Linger's local PolyStrata engine strictly requires either an NVIDIA GPU (with CUDA support, ≥8GB VRAM) or an Apple Silicon Mac (M-series with ≥16GB unified memory). Systems running integrated graphics, AMD GPUs, or CPUs only cannot download or execute local models.

Options:

  • Option A (BYOK / Cloud Runtime): Use Claude Code, Codex, or BYOK with cloud API keys. Linger will operate as a cloud agent without running local models.
  • Option B (Rent a Cloud GPU): Spin up an on-demand NVIDIA GPU to test Linger's PolyStrata local model stack.
Disclosure: links marked with * are affiliate links. If you rent through them, we may earn a commission at no extra cost to you.

Rent an On-Demand GPU

Rent an hourly NVIDIA RTX workstation on Vast.ai or RunPod to test local inference without buying new hardware.

5. Intermittent 503 from gemini-3.8-flash / gemini-flash-latest

Symptom:

Connection testing or agent queries return intermittent HTTP 503 (Service Unavailable or Model Overloaded).

What it means:

Bleeding-edge preview endpoints like gemini-3.8-flash or alias aliases like gemini-flash-latest experience occasional upstream capacity constraints on public developer tiers.

Fix:

Fix: Retry the request after a short interval, or switch the BYOK Model ID to the more stable gemini-3-flash-preview.

Still Stuck?

If you're encountering an unlisted error code or need direct assistance configuring your system, book a 1-on-1 remote guidance session ($80–150).